The control of air should come under scrutiny when planning a manufacturing process, and it is essential to consider general maintenance issues involved in the management of air handling units, as well as how modern vibration monitoring techniques can maximise their performance. Air control has been used in the preparation of medicines for centuries ever since witch doctors began air drying their herbs and spices. Even today, the practice remains popular in some corners of the globe; in 2011, the National Geographic Channel television series The Witch Doctor Will See You Now showed dried animal medicinal products on sale at a Kowloon shop, including deer antlers sliced into thin strips and then ground into a powder, supposedly to promote bone health. In the west, air handling for medicinal purposes is a very different business, requiring the skill to manage machinery that can maintain air conditions within precise limits during the manufacture of pharmaceutical supplies.

Air handling units are key to maintaining the quality of output on a pharmaceutical production line. Consistent indoor air quality must be maintained, with no sudden changes to air flow rate, temperature or humidity that could potentially compromise production quality. To ensure that these levels are carefully managed, machinery must be well specified, maintained and run, since a mechanical failure can make a degradation in air standards almost inevitable.

So how can operators protect themselves against such eventualities? To learn how best to optimise your systems, it pays to consider the general maintenance issues surrounding air handling units, and then look at the relevant vibration monitoring techniques that can ensure consistent air quality. In addition, we need to understand what vibration sensors are and how they function in order to install and use them to their full potential.

Accelerometers and Air Handling Units

A typical air handling unit consists of a large metal enclosure with removable panels, behind which we find air filters, coils that circulate hot water or steam for heating and chilled water for cooling, and a fan and motor assembly, as well as associated bearings, shafts, pulleys and belts. By evaluating the state of the rotating elements of the air handling unit, engineers can exercise an efficient preventative maintenance programme, and a highly effective way to carry out condition monitoring is to use vibration sensors.

Vibration sensors, which measure a quantity of acceleration and are therefore a type of accelerometer, typically contain a piezoelectric crystal element bonded to a mass. When the accelerometer is subject to an accelerative force, the mass compresses the crystal, causing it to produce an electrical signal that is proportional to the level of force applied. The signal is then amplified and conditioned using inbuilt electronics that create an output signal, which is suitable for use by higher level data acquisition or control systems. Output data from accelerometers mounted in key locations can either be read periodically using sophisticated hand-held data collectors, for either immediate analysis or for subsequent downloading to a PC, or else routed via switch boxes to a centralised or higher level system for continuous monitoring.

Accelerometers can be divided into two categories, AC and 4-20mA. Each of these accelerometers is capable of delivering a different level of data aqcuisition, a key fact to consider when specifying a vibration monitoring programme for air handling units. 4-20mA devices are typically used with a programmable logic controller (PLC) to measure lower value assets, such as fans and pumps, while AC accelerometers can be used with a data collector for monitoring the condition of higher value assets. 4-20mA devices are generally considered to be the ‘cost-effective’ option and, like AC accelerometers, are highly effi cient in detecting imbalance, bearing condition and misalignment. There are also occasions when AC accelerometers are specifi ed for their ability to identify further issues, such as cavitation, looseness, gear defects and belt problems. To see how these different sensors might be applied, let’s return to our examination of a typical air handling unit.

Planning the Programme

A series of options are available when planning a vibration monitoring programme for air handling units. Fans, for example, may require as many as eight vibration sensors, depending upon their specifi cation. A supply fan may need a vibration sensor installed on both the drive-end and non-drive-end bearing if it is a direct-drive type. However, when monitoring a non-direct drive fan it is advisable to add two accelerometers on the journal bearings of the gear shaft.

By mounting 4-20mA sensors on to the bearings and shafts of the air handling unit, velocity levels can be fed back to a PLC, allowing vibration trends to be effectively monitored. If engineers also require more-in-depth vibration analysis via a data collector, other options are available. For example, a dual output sensor that provides not only a 4-20mA output but also an AC output will deliver more detailed information on balance and alignment. A further option is provided by fixed AC sensors, which can be hard-wired to switch boxes located in accessible positions outside the air handling unit. This enables vibration data to be collected routinely and safely, although the data gathered is limited in its potential, since measurements relate only to the time at which they were logged.

Engineers should be aware of the fact that there are also sensors available for use in installations where there is limited space for installation or access. For example, side entry sensors can be used where access is difficult, such as in proximity to belt guards, while smaller air handling units can be effectively and conveniently monitored using compact, small footprint sensors.

When specifying equipment, choose a supplier with a broad range of options and expertise in a variety of sectors. For example, a number of configurations and finishes are available for switch boxes, but stainless steel units are often compulsory in pharmaceutical applications, so you need to select a balance between costeffectiveness, legislative requirements and reliability.

Installation Issues

There is no point in specifying the ideal equipment for your application and then failing to install it correctly, so again it is best to use a well-established supplier who will offer valuable advice. For example, engineers should mount accelerometers directly onto the machine surface on a flat, smooth, unpainted surface, free from grease and oil, that is larger than the base of the accelerometer itself. Another useful tip is to ensure that the accelerometer is positioned as close as possible to the source of vibration. If conditions (and product warranties) allow, the preferred mounting technique is to drill and tap a thread directly onto the machine so that an accelerometer with an integral ¼-28UNF, M6 or M8 mounting thread can be screwed into place. This ‘drill and tap’ method can also be used to fix a mounting stud, to which an accelerometer can then be attached, and specialised installation kits are available for performing this task. It is important to take care and use the right tools for the job, as tightening the sensor outside the appropriate torque levels can damage equipment or reduce its effectiveness. For example over-tightening can damage the sensor by stripping the thread, while undertightening will lead to inaccurate readings due to poor contact with the vibrating surface.

If drilling and tapping is not an option, the next best thing is to attach mounting studs using adhesive. The issue to be aware of here is that you may need to consider the temperature present within your application, and choose an adhesive that is capable of coping with that temperature. For applications in temperatures up to 100°C, a metal-filled epoxy adhesive would be the appropriate substance to use.

Having installed accelerometers as carefully as possible, ensure that the accelerometer cable is clamped to the body of the accelerometer itself with a cable tie. This will not only prevent strain but also avoid the false readings that can be generated when loose cables make excessive movement.

Although there are several important specification and installation issues to be considered, the result of implementing a vibration monitoring programme will be well worth the effort, extending the operating life of equipment beyond recommended maintenance intervals and guarding against the expenses generated when increases in vibration lead to machine failure, downtime and unwelcome reductions in production volume or quality.


Read full article from PDF >>

Rate this article You must be a member of the site to make a vote.  
Average rating:
0
     

There are no comments in regards to this article.

spacer
Chris Hansford is a qualified electro-mechanical engineer with over 30 years’ experience in the vibration monitoring industry. In 1986, he was involved in the formation of a sensor manufacturing company and, as Managing Director for 20 years, successfully grew the business and gained a wealth of commercial experience within the UK market. In 2006, Chris moved on to set up Hansford Sensors Ltd, a manufacturer of accelerometers and ancillary equipment.
spacer
Chris Hansford
spacer
spacer
Print this page
Send to a friend
Privacy statement
News and Press Releases

Huge CPhI & P-MEC China a direct result of surging manufacturing

Shanghai, 22 July, 2019:CPhI and P-MEC China – organized by China Chamber of Commerce for Import & Export of Medicines & Health Products (CCCMHPIE), Informa Markets, and Shanghai Sinoexpo Informa Markets – saw record numbers of attendees as the pharma market in China continues to grow. The three-day Shanghai event featured 3,200+ exhibiting companies, spanning the entire pharma supply chain, and provides a strong indication of the market’s overall growth patterns and future development.
More info >>

White Papers

Planning the Execution of a Viral Clearance Study

Eurofins BioPharma Product Testing

Viral clearance studies are a necessary component of any regulatory submission for clinical trials or commercial product approval for all biopharmaceutical products. These studies are performed to evaluate the capability of the purification process to remove or inactivate viruses that could potentially contaminate the starting material. They are complex studies that require substantial financial and personnel resources, as well as specialized scientific expertise to perform. As such, viral clearance studies are often performed at a qualified contract testing laboratory rather than in-house. When multiple parties are involved in this process, clear communication and a comprehensive understanding of the approach and timeline is critical.
More info >>

 
Industry Events

FlyPharma Europe

22-23 October 2019, Copenhagen, Denmark

The FlyPharma Conference Europe 2019 is aimed at forward-thinking individuals and businesses that are ready to uncover the potential in their pharma supply chain. The event offers an interactive platform to discuss current and future challenges within pharma and cargo, with topics including market trends, cold chain innovations, latest regulatory demands, security technology, and how to encourage collaboration between supply chain players. There will be plenty of networking opportunities, including a complimentary evening networking event, where delegates can meet and catch up with senior and executive pharma and cargo professionals – gaining strong, new industry contacts and building on existing ones.
More info >>

 

 

©2000-2011 Samedan Ltd.
Add to favourites

Print this page

Send to a friend
Privacy statement